Useful Information Regarding Insulation Tester

By Barbara Morgan


Under perfect conditions, current that is allowed to pass through a conductor is supposed to go all the way through to the destination intact. However, given that there are no perfect conditions, current leakage occur and electrical energy is lost along the way. This happens for different reasons. Resistant sheathing is usually used to clad conductors in order to try and prevent or minimize the loss of electrical energy due to leakage. This is worth knowing about Insulation tester.

Sometimes the current is lost if the insulating sheath is made from imperfect materials. Machinery and electric circuits are greatly affected when there is leakage of current due to imperfect cladding. Such a case can be controlled by frequently testing the insulating material to determine its perfectness. Testing the material frequently can help to catch problems in advance before injuries or device failure happens because of loss of current.

This testing process is done using a pieces of equipment referred to as an cladding tester. The equipment tests the integrity of the cladding by measuring its resistance to the flow of current across it. If the cladding is of high quality, it means that very little current will escape through it. On the contrary, if the cladding offers very little resistance, then a higher amount of current will flow across it.

When measuring the quality of cladding, testers measure different types of currents. Absorption, capacitive, and leakage current are the three kinds of current that are measured. When voltage is first applied to a conductor, there is an initial burst of current that flows. This initial burst of current is referred to as capacitive current.

Capacitive current can be equated to the volume of water that comes out of a pipe immediately a tap is opened. Once the tap is opened, water usually flows out at a higher rate but as the pipe gets filled with water completely, the rate drops rapidly. For the case of a conductive material, the amount of current flow drops once the conductor becomes fully charged.

Absorption current is similar to capacitive current in that it starts out high but then drops. The only difference between these two kinds of currents is that absorption current drops at a much lower rate compared to capacitive current. The gradual drop in absorption current is due to the storage of potential energy in the cladding. Absorption current makes an important part of the time resistance method of cladding testing.

Conduction current is the other name used for leakage current. This current is present through and over the cladding and it is small and steady in nature. The increase in leakage current implies deterioration of the cladding over time as well. In insulation test meter, the rise in leakage current is indicated as a reduction in resistance.

Currently, different types of cladding testers are available in the market. Different manufacturers from different countries produce these devices. The manufacturer of the equipment largely influences its quality. Different models of cladding testers are used to perform different functions. For instance, some testers are designed to perform testing in residential settings while other testers are meant to be used for testing equipment in industries.